Onan 5500 generator code 15. com Google Click Here to Login: Files: Vendors .

Onan 5500 generator code 15 The electronic governor, 151-0752, on . D. Check the manual for your specific 5500 model and see what procedures you have to do. Damon Owners Club Workhorse My 2005 Onan 5500 was shutting down and displaying a code 33 I just pulled the code from the generator, 10-15-2024, 10:40 AM THenne1713. Join Date: Jul The primary codes are 1, 2, or 3 blinks, so yes there is a primary code 1. Sign in or Create account to save products and never miss out on your equipment needs. 2017 that identifies a hot air re-circulating problem that can cause the genny to shut down and throw a "36" code. 0 QD mysterious start: Macado: Travel Supreme Owner's Then let the generator run for about 15 minutes to make sure the code has been cleared. When we got home, I changed the oil and filter, and the air filter. A Primary code of 1 means can have a secondary code of 33 or 34; a primary code of 3 can have secondary codes ranging from 11 to 42. Why of course. Only trained and experienced personnel with knowledge of fuels, electricity and machinery hazards should perform generator set installation procedures. Mark as New; Bookmark; Subscribe; Report Inappropriate Content ‎Jun-13-2014 07:37 AM. Will the unit actually start and run as long as you hold the start switch, or After running for 30 minutes or so, it fails and gives fault code 15 which in the manual is ‘Low AC Frequency’ It will immediately restart, then run for a similar period. Went to do my monthly exercise on the generator the other day and it would shut down after a few seconds and give the code 13, Onan Marquis Gold 5500 Code 13 shutdown. 03-20-2018 09:15 AM: Onan 5500 Marquis Gold Generator: Ontherun: RV Systems & Appliances: 6: 09-12-2017 02:09 PM: The fault code 58 is displayed by your Onan generator when the temperature of exhaust gases is higher than 1200 degrees Fahrenheit for a duration of 2 seconds. FMA4fun provides our members annual rallies, educational seminars to help make the most of your RV and keep it in good working order. Diag light How to Clear a Fault Code on Onan Generator Locate the primer button on the Hold the primer button down for at least 30 seconds. Sometimes it will run for an hour, sometimes only 15 or 20 minutes, and sometimes it will shut down Onan generator runs then stops - iRV2 Forums I have a 2018 Momentum 351M and I am having a few issues with it, one of which is the Onan 5500 generator shuts off about 15 minutes after being started cold. ran it for about 5 minutes, then let it sit for 15. What's the history on this generator? What has been replaced? About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright I saw someone struggling with a Code 14 on their Onan 7000 Gas generator. 41 (Controller unable to sense field or output voltage) _____ Paul Bristol Kodiak Cub 176RD Nissan Pathfinder 2015 Tags: onan: You may I have a Onan 5500 Marquis Gold Model 5. This is because the old oil takes a long time to drain, The Onan 5500 generator would use a 15W-40 (or straight 30) >> How to Fix Fault Code 15 on Onan Generator? >> How to Fix Fault Code 36 on Onan Generator? >> How to Fix Fault Code 33 on Onan Generator? Looking for what kind of oil an Onan 5500 generator take? Look no more. Multiple causes could be Won’t stop after 15 min also won’t Show a fault code. Browse I have a 2006 Weekend Warrior with a 5500 Onan Marquis Gold shuts down. C. Jun 17 We hit a heat wave and had to run our generator an Onan (HGJAB901A), it quit and threw a Code I believed was " Low Onan Generator Code 58 in Technical Issues Aug-16-2024; Norcold N8xlt intermittent on LP in Technical Issues Jun-15-2023; 5500 Onan starts then dies, help please in Technical Issues Nov-11-2021; Onan 5500 code 14 or 41 iRV2. 15 PM: Onan Fault Code: Fossilhog: MH-General Discussions & Problems: 4: 08-06-2010 11:53 AM: Onan 5500 code 14 or 41 iRV2. com Google Click Here to Login: Files: Vendors Registry. Lots of propane in the tank. Generator Shut-off--Fault code 27: Old Scout: Alpine Coach Owner's Forum: 5: 06-20-2008 05:39 AM: Onan 5500 trouble code: Carvin Marvin: RV Systems & Appliances: 4: 10-26-2007 04:07 PM: Onan GenSet - loose wires & false code 27: Dale777: Alpine Coach Owner's Forum: 2: 06-29-2007 06:01 PM: If you do something wrong and it's your fault, JRBurn After leaving 5 months in storage, generator tries to start but stops when button is released. I am running an Onan 5. 2003 5. One of the simplest and cheapest ways to avoid the fault code 14 is to exercise your generator. 5 HGJAD-2558C with the hydraulic option on an F350, gasoline Superduty chassis with a 35ft Versalift bucket (Old Verizon truck) with controls in the bucket and at the rear of the chassis. What can be checked or how do I repair ? ? ? Engine Mechanic's Assistant: I understand that youre experiencing a fault code 15 (underfrequency fault) with your Onan 4KYFA26100L generator, and it stalls out after running Avoiding Onan Generator Fault Code 14. What's new. The main source of sustained electric power supply in your RV is the generator, and for it to reliably produce electricity you need to keep it well maintained and remove any faults that may crop up. Onan Micro quiet 4 K My Onan 5500 has always shut off in 95 degree weather. It flashes a 36 fault code. Frequency 60 Hz Certification Tier 4 Final / Stage IV, EPA Tier 4 Motorhome and RV Generators Quietest in its class. If the genset is not even starting, it should not be setting this code. This code will only blink twice. Forum Rules. I have a onan 7000w generator gas that has fault code 15. justanswer. From https://www. Give me a couple of minutes to thoroughly read your concern and respond. 52 Satisfied Customers. M. 5HGJAB-6755J Serial #: D120326173 The generator will start and immediately shut down. Took to a Cummins certified mechanic and had the following work done (drive system rebuilt under warranty, new carb, new rotor, new control board, new pins for switch, new oil and oil filter). Then I get a fault code 36. We´ve got you covered. I have a 2007 onan 5500 generator in my toy hauler, I replaced the fuel pump last summer, was running great, I went to start it a couple months later, it starts and immediately shuts off in like 2 seconds, I found that the fuel solenoid in the bottom on the carb is closing right after starting. Posts Have an aggravating issue with my Onan 5500 generator, that hopefully someone on here as a solution. i have a 5500 ONAN MARQUIS with CODE 33 and will not CRANK CHECKED VOLTAGE,OIL,FUEL all are OK My Marquis 5500 gold Onan generator calls for 15-40 oil is shell rotella t an oil I can use? Tech4you. Reply Onan 5500 generator code 58 - Exhaust Gas Temperature Sensor Shutdown Repairs & Maintenance - '15 RAM 3500 SRW 4x4 Aisin Crew - '17 Maverick X3 RS 12-04-2023, 07:15 PM #2: chuckster57. Oil level is fine, 3/4 tank of gas. Onan Generator Problem - code 37: Shake: Thor Industries Owner's Forum: 2: 09-05-2014 05:45 AM: Onan 10K Diesel code 36: thahn: RV Systems & Appliances: 1: 09-10-2013 06:02 AM I have a Onan 5500 propane gen set and about a month ago it started quitting after I may have to buy a small generator just so I can pull the 15 amps that I must it has to receive power to close. Sep 21, 2022. 5hgjab locate wires P1-15 and P1-20. com) I have a 2013 Voltage toy hauler with a Cummins Onan RV QG 5500 EVAP gasoline generator, with 45 total hours. com Google Click Here to Login: Files: Vendors. You should be able to look up the code number in the Onan manual or online. I just received a Fault Code No. On the Onan 4000, you press and release the start button on the generator itself, and a lamp in the start button does a 2 digit flash code that tells you the reason for the last generator shutdown. The way the 4000 is made the side cover MUST be on or the air cooling will not blow air across the engine and generator. You may be surprised at the sources for this fault code as one is you need to change REPLACE THE FUEL PUMP ON A ONAN MARQUIS GOLD 5500 GENERATOR. 2009. GENERATOR FIELD SENSE FAULT—CODE NO. When trying to start it for a maintenance run, I somehow flooded it. it will start right back up and keep shutting What is code 44 . You should check the load and altitude settings, air filter, exhaust Code 15 is Under Frequency. We have a 5500 Onan. Note the highlighted letter code, in this case P, which denotes the specification type of the particular generator, which can then be referred to as spec P. Onan 5500 generator code 58 - Exhaust Gas Temperature Sensor Shutdown Repairs & Maintenance - '15 RAM 3500 SRW 4x4 Aisin Crew - '17 Maverick X3 RS 12-04-2023, 07:15 PM #2: chuckster57. I've not really used it beyond a test hour initially and running it for 15-20 mins regularly to keep it in working condition. This should give you and idea of what's involved to correct this 15: 12-19-2017 11:39 PM: Onan quiet 7500 I have an Onan Emerald Plus 4kw generator (BGE spec. 15 (Underfrequency Fault - Engine governor unable to maintain rated frequency). 4. I have an Onan 5500 (HGJAB-6755D) that won't start. Press Stop once Onan generator model 5500 starts runs for about 15 seconds and shuts off. The last fault code can always be retrieved from the start switch. My generator has suddenly started shutting down after 15 mins or so and giving code 36, which is pretty generic. I start the generator from the inside control panel and it has no problem starting and running perfectly even under A/C load. What is Fault Code 35 on Onan Generator. Anywhere from Genset will not stay running. Am I looking at a Stator and By chatting and providing personal info My onan 5500 generator on my camper is shutting off. had low oilchanged and. Here is a quick video showing you how to correct a Code 14 and Code 15. Do you have any ideas as to the possible By chatting and providing personal My Marquis 5500 gold Onan generator calls for 15-40 oil is shell rotella t an oil I can use? Tech4you. There are several causes that may lead to a generator producing less than 108 volts of alternating current. Reconnect the generator to the power source and power it back on. Forums. H). Two blinks indicates a low oil pressure fault. I came back and started it again. Allow the generator to run for 15 minutes, to make sure there isn't a continuing issue. Single i think. So my RV generator is now flashing a 47 code. Q: How can I diagnose fault code 33 on my Onan generator? How to Fix Onan Generator Fault Code 36? Some solutions to fix the Onan generator fault code 36 are: 1. I have an Onan 5500 lp generator it is brand new 10 hrs had oil leak My Marquis 5500 gold Onan generator calls for 15-40 oil is shell rotella t an oil I can use? Tech4you RV Generator repair for 15 years Certified in Onan, Generac,Kohler and Power Tech 1. It's 36 how do I reset it? It's a Heartland Road. Automatic Generator Start for Onan 5500 Generator. The generator would sometimes run for an hour, sometimes 5 minutes and everything in between. Once it is warmed up, it only runs for a few minutes. New battery. It has 1500 hours on it. That is encouraging. Forum: Replies: Last Post: Onan Generator Surging: jimemeone: RV Systems & Appliances: 6: 07-12-2019 10:54 PM: Onan 5500 Generator Surging: bigben: Thor Industries Owner's Forum: 4: 01-15-2016 07:17 AM: Onan 5500 Generator Surging: bigben I found this using a Google Search for Onan 5500 Marquis Gold Service Manual and clicked on Rocky Mountain Generators Link, give it a try. any fixes ? onan 5500 code 15 - Thor Forums Journey with Confidence RV GPS App RV Trip Planner RV LIFE Campground Reviews RV Maintenance Take a Speed Test Free 7 Day Trial × #15 I went to camping Onan 5500 issues running / reading codes 36 and parts Hi all Im new to this forum, thankfully I found in a net search. The Onan advice only addresses external causes, but there are internal possibilities as well. There are four potential causes of this, and half of them are very easy to fix. 41 (Controller unable to sense field or output voltage) _____ Paul Bristol Kodiak Cub 176RD Nissan Pathfinder 2015 Tags: onan: You may also like: Onan generator fix for the no run condition #redbanksclassics #cummins #onan #generator 6. By chatting and providing personal info, you understand and My onan 5500 will run 15 minutes, then shut off. 16. Error code appears to be 34 Re: Onan 5500 First of all, Thanks for the link to the Trouble Shooting codes. 2015. You can call Onan corporate customer service at 1 800-286-6467. JustAnswer Customer: 3 weeks ago we replaced Customer: My onan 5500 will run for approx 15 minutes, then shut off without throwing a fault code. Explorer Options. This is what the manual said: OVERFREQUENCY FAULT—CODE NO. Has a new. Changed. I have a 2011 Thor Hurricane Class A gas Motorhome with an Onan 5500 generator and 2 A/C units. Everything I have read about code 33 is related to overheat condition. Looking. Onan CT Kit. Oil changed recently. There is Following a fault shutdown, the indicator light will repeatedly blink 2, 3 or 4 blinks at a time. Onan 5500 Altitude Enjoy the latest from our Frazer ‘How To’ series!Our goal is to provide educational and informative content for proper operation and maintenance of your Fraz Some people do confuse the 3 blinking lights as fault code #33. Press Stop three times within five sec-onds to restore blinking. Onan gold 5500 shows code 13 Will only run when you hold in starter button. The generator would run for 15-20 minutes, then surge like a lawn mower does when it runs out of gas and shut down. Usually an AC unit and an electric heater would do the trick. Location: Memphis, TN. 5K Onan Generator Code 45 Generator would not start after Coach fuel pump replacement (tank had to be dropped). Not every generator is designed in the same way. The generator cranks and runs fine with the a/c units going for a few hours, but then would trip the 20 amp a/c breaker located on the side of the generator. Hi, I am getting fault code 15 on my QG 7000. 24. What is Fault Code 13 on Onan Generator. New posts. hazards shall remove, dismantle and dispose of the generator set. On a previous camper with an Onan 5500. Thread starter Gbettner; Start date Oct Aug 15, 2018; Onan Generators; Replies 13 Views 2,924. 15: 02-22-2016 01:09 PM: Onan Generator shuts down when load is disconnected: descour: RV Systems & Appliances: 4: Customer: I have an Onan 4KYFA26100L , fault code 15 (underfrequence fault) that will start but stalls out after running just a few minutes (3 mins tops). The generator has been working fine and has has about 500 hours on the Hobbs meter. 5HGJAB-901C 5500 Watt Gas Generator Fault code retrieval - the generator runs for a second or so then. Troubleshooting Onan Generator Fault Code 19 Fault code 19 happens when the control board detects that the governor actuator’s circuit is open or shorted during the attempt to start the generator. Explore our comprehensive selection of genuine Onan generator parts. Code 15 - Under Frequency Code 19 - Governor Actuator Overload Code 23 - Low Oil Pressure Cutoff Switch Code 27 - Frequently Asked Questions about Onan Generator Fault Code 3 Flashes: How to Fix. Onan: Onan Knowing what the code means and how to fix it is information you need to know. Electricity, fuel, exhaust, moving parts, and batteries present hazards which can result in severe personal injury or death. 300-4155 Control Board 15 Application of External Field Flash using Diode 15 300-5299 Control Assembly 16 RV Generator Measurement Sheet 17 Issued 6/08; regulator or generator can proceed, the Onan engine must have oil and fuel, be in running condition and the 12-volt battery charged. : 5500 etc? If it is a 5500 , it will draw about 45 amps at full load. Help, After getting help from this forum to get the Model 5. The trailer has a factory installed Onan 5500 (model # 5. Besides, it doesn't seem that the Onan would generate the code 47 if the solenoid was just firing off on its own. • Generator output connections must be made by a qualified electrician in accordance with applicable codes. Onan code 31. Site Team . code 15. If I start it again, the engine will run (and sounds fine) but it must be in a fault mode because it will not power anything Onan generator fault code 41 iRV2. After cooling down, it will restart, run for about 10 minutes and shut off after surging a few times. thus if the fuel level is lower than 1/4 full the onan pick up tube will not be able to draw any fuel. Check The Carburetor. Some say it could be the magnito, some say brushes, some say My Marquis 5500 gold Onan generator calls for 15-40 oil is shell rotella t an oil I can use? Tech4you. Model is 7HGJAE-1912K. Have a secondary fault code of 14. Generators used onan marquis gold 5500 generator model: 5. Onan fault code 47 iRV2. There tech support was fantastic help. Thread starter cfuller201; Start date Mar 18, - Produces a fault code of 32 ? low cranking speed sense. Exceptionally low vibration levels. It might be an old code. 14 (Engine governor unable to maintain rated frequency) Corrective Action: See an authorized Onan dealer. Here is a representation of the tag on Onan QG 4000. Code 36 may be a bit difficult to understand as it is used often by the control module. 1. com Google Click Here to Login: Register: Files: Vendors Registry. Was the problem that the generator wouldn't start, or wouldn't crank? I have been in your shoes. What is code 44 . 2015 Seismic 3210 5th Wheel Toy Hauler 2021 GMC Sierra Denali 2500 HD Duramax 2016 Weber Smokey Mountain 18" Brisket & Rib Factory Many Onan 5500 owners recommend running your generator with a load for 15 to 20 minutes to heat the oil up before changing it. 11-27-2017 05:15 AM: Onan QG 5500 just quits code "1" Tincup: RV Systems & Appliances: 27: 11-22-2016 12:51 PM: Onan Marquis Gold 5500 quits with hard brakes: ajdauphin: RV Systems & Appliances: 6: 09-02-2015 06:08 PM: Fixing RV generator Hi folks, I have a GD3270BH from 2019 with a factory installed Onan 5500 (QG 5500 LP, HGJAB series K). Warwagon. I have an Onan 5500 Marquis gold generator that I just replaced the carberator and still doesn't start. My Marquis 5500 gold Onan generator calls for 15-40 oil is shell rotella t an oil I can use? Tech4you. Reassemble the brush block in the generator – Magic Marker mark to the top. 5HGJAB-6755K). com Google Click Here to Login: Files: Vendors You will find the Onan Generator Service Manual. 3/4 tank fuel, oil is full, primes for 30 seconds, will not start after cranking. The block will break if installed upside down. Our onan 5500 gas generator will start and run fine for 30 minutes to an hour then shuts down and will not restart until it cools down for 15-20 minutes. I have an Onan 5500 generator in a toy hauler and it shuts down after running only a few minutes with a code 58. It starts and runs for sometimes 20minutes or maybe 5 minutes. 2020. Some generator set installation procedures present hazards that can result in severe personal injury or death. To solve the fault code 37 on Onan generator, just check and follow the steps below: >> How to Fix Fault Code 15 on Onan Generator? Troubleshooting an Onan Marquis Gold 5500 Generator >> Check out the video below: References. _____ Running down the road the other day and fired up the onan 5500 gas generator. Fault code 15 happens when the generator is unable to provide AC with a frequency above 54Hz. It is a Onan 5500 gas with only 20 hours on it. Looking for a REVGroup Motorhome club? Fleetwood Motorhome Association (FMA) is the National Owners Group for all Fleetwood, American Coach, Holiday Rambler, and Monaco RVs. Cranks over fine. Tools needed We have an Onan Quiet Diesel 10000 (10HDKCA) that will run for a while and then shut off. About a week ago It will run if you. 2010 RJay suggested "checking slip rings for corrosion. Also show how to check fuel pump fuse, and my favorite troub Fault code 15. Car Specialist. Started fine and ran for approximatly 20 minutes then cut off. The carburetor is responsible for starting the generator because the fuel travels to it when the fuel valves are released. Set your meter to ohms, and connect the RED lead to a clean ground. What model is it , i. When your Onan generator stops due to any type of fault, the status indicator on the control switch will start blinking in quick succession with pauses in between. 15 years of small engine and generator service and repair. Apr 21, 2022. If you read your Onan manual it tells you how to use the Generator's manual start button to show the fault code it saved the last time it stored a code. Model number 5. The solution is to either clean the Customer: We have an onan 5500 generator throwing code 15. #15 I had a similar issue with a 7K gen of Onan generator fault code 41 iRV2. On page 18-14 your will find code 25 and corrective action. Bad rotor or brushes? This generator only has about 50 hrs on it and 3. I had a mobile RV repair place look at it and they replaced the fuel pump, but that wasn't the problem. This can happen in three general situations, first, the generator engine is unable to provide the amoun Code 2 - Low Oil Pressure. rjgibbons408. I just started getting a code 15 (under-frequency) on my Onan 5500 LP genset. After asking around, everyone said that it was probably a bad breaker. GmPlus72. 5 yrs old. Onan 5500 showing code 47. 15. Onan 5500 Generator: Rcandvicki: RV Systems & Appliances: 7: 07-23-2014 02:50 PM: Maintenance on a Onan 5500 watt propane generator: Jasper7821: RV Systems & Appliances: 4: 01-25-2014 03:52 PM: Can a Onan 5500 watt Marquis Gold be converted to propane: Jasper7821: RV Systems & Appliances: 22: 01-23-2014 08:45 PM: Onan 5500 Hopefully he had the Onan side cover on when he did his shop test. Certified on Onan and Generac generators. The generator would be This is how you replace the fuel pump. What that means is that the RPM level while starting was under 180 for at least 2 seconds. status light ok. Onan 5500 marquis gold code 12 over. Please follow these 15 Views 972. I run it at least once a month for 30 Home. It has been a year and it is a 2006. 300-4155 Control Board 15 Application of External Field Flash using Diode 15 300-5299 Control Assembly 16 RV Generator Measurement Sheet 17 Issued 6/08; Revised 9/17 regulator or generator can proceed, the Onan engine must have oil and fuel, be in running condition and the 12-volt battery charged. I have just replaced the PCM. Join Date: Jul 5500 Onan vs 7000 Onan: HUGHP: MH-General Discussions & Problems: 10: 07-16-2016 08:09 PM: Onan 5500 Generator No Fuel Problem: live2ride: RV Systems & Appliances: 3: 04-02-2015 09:13 PM: Onan 5500 gas generator starter problem: rca: RV Systems & Appliances: 6: 07-08-2013 08:09 PM: onan generator 5500 LP: 24him: Travel Trailer Onan 5500 fault code 58 how do I fix that. 48 (Controller unable to sense field voltage) Corrective Action: See an authorized Onan dealer. When it shuts off and I check the code it comes up 47. 15-20 amps would represent 1/2 load and a little more would be 3/4. Original problem, would not crank throwing a code 32. Frequently Asked Questions about Onan Generator Code 14: Causes & Fixes Q: What is Onan Generator Code 14? A: Onan Generator Code 14 indicates a fault in the generator’s ignition coil circuit. onan 5500 rv generator code 32. Yes, fuel and air are required to make any diesel engine run. This speaks to the reliability of Onan generators when they are properly maintained. " HTML code is Off. Going over the details of all of them is beyond the scope of this article, and for some of them, you will not be Good afternoon everyone, Onan Marquis gold 5500 genset S/N 5. Gulf Streamers Club Ford Super Duty Owner. We were on/off generator power from Wednesday to Saturday, and the temps was around 105. RV tech since the beginning of the millenium. 8. I have a Tiffin RV with a 5500 generator. Touch the black lead to each of I just purchased a Jayco Seismic TH from camping world in Dec. You should check the load and altitude settings, air filter, exhaust system, fuel lines, pump, and filter. The electronic governor, 151-0752, Onan fault code 32 is a low cranking speed. #15 I Onan Marquis 5500 Generator - YouTube. Specialities include: Any knowledge on onan 5500 generators? 2006 onan 5500 marquis gold. 4yrs. That generator set are solely responsible for its safe operation. Save to. Here are some frequently asked questions and their answers regarding fault code 3 flashes on Onan generators: Q: What should I do if I see fault code 3 flashes on my Onan generator? A: Start by checking the fuel level in the tank and refuel if necessary. 2002 Monaco lapalma. Generator set operation, maintenance, and installation must comply with all applicable local, state, and federal codes and regulations. PAYPAL ACCOUNT:https://paypal. No matter how often you use your RV you should take a little time to give the generator a little work out to keep it in top shape. Add to cart. I have seen an article where the air-cool does not have a code 33, as stated. But the handbook for Onan says that you need to check the fuel supply and fill the gas tank as needed. the onan pickup tube is supposed to be at the 1/4 full (or so) level of motorhome tank. $15. Model #: 5. 15 hours Onan RV QG 5500 EVAP with a Furrion F50-ATS. The electronic governor, 151-0752, on Models BGM and NHM, Spec B and later, must be functioning properly. It has only 70 hours on it and it has run just fine until recently. Access to FREE repair services by qualified In this video I go over how to get to the second level error or fault codes on Onan generators. I My Outlaw has an Onan marquis gold 5500 generator, I don’t recall the code it spit out, something regarding unexpected shutdown (maybe 5-7). D 2006, war was beginning. 5HGJAB-1119J S/N J160106760 Spec J running. com/ythiJustAnswer Customer: The onan generator I am looking at has a fault code 15. 5--- code 37 generator dies in seconds consistently I have an onan 5500 gold marquis generator that starts and dies after 7 seconds. Do not call a dealership they're going to have you go in for service. See service manual. Please follow these instructions by using City, State, Country in your location! Incomplete applications will be REJECTED. Does anyone see any issue with using Rotella engine oil 15w 40 for a Onan 5500 Generator? https: I have been using Rotella 15-40 in my 5500 Onan for about 10 years with no issues. There is more to learn about code 36 and how to fix what ails your generator. 48. The mighty Celica reached the end of its reproductive cycle and its population began a gradual but ever increasing decline. Similar Threads: I have an Onan 5500 in a 2005 Fleetwood Flair (specs are in the image at the bottom). A code 15 indicates an underfrequency fault. It shows that the generator is low Error Code 15 “Under Frequency”. it does have 4667 hours on it as well. pdf (rockymountaingeneratorsupply. Before proceeding with evaluation of the controls, regulator or generator, the Onan engine must have oil and fuel, be in running condition and the 12-volt battery charged. I believe it I have a Class A gasser with the 5500 Onan generator. 55,202 Satisfied Customers. of 2014. Here are some common questions related to fault code 33 on Onan generators: Q: What does fault code 33 on an Onan generator mean? A: Fault code 33 on an Onan generator indicates an open or shorted circuit on the generator control board. Hank F. 22. model number 5. 15 PM: Onan Fault Code: Fossilhog: MH-General Discussions & Problems: 4: 08-06-2010 11:53 AM: Onan gold 5500 shows code 13 Will only run when you hold in starter button. jmarnell; Sep 21, 2022; Generators / Transfer Switches (ATS) Replies 0 Views 3K. Cummins Oman RV QG 5500. I have a 2007 onan 5500 generator in my toy hauler, NO ZIP CODES! Your account is then manually checked and approved. I just went to start it as usual to make sure all is good and it starts but immediately shuts off. 5HGJAB-10388D Spec D Onan: Onan Marquis gold 5500 code 47. In A. Cummins-Onan 7500 quiet diesel generator fault code 25 iRV2. Use our RV Green Label Parts Reference Guide to ensure the right fit. 2,578 satisfied customers. Part # 300-4623-27. I checked the brushes and they are Onan 5500 Generator Surges & Quits Intermittently. 5 hp lp Onan marquis 5500 generator offroad midwest forum irv2 If your Cummins Onan QG5500 gas generator is not producing power (flashing red light), running rough or surging, or shutting off with a Code 45 fault, this v No start power to Onan 5500 generator in Technical Issues Oct-09-2024; Ram truck ABS/HCU recall in Tow Vehicles Sep-16-2024; yes another ryobi issue in Technical Issues Jul-15-2024; Transfer switch location in Technical Issues Jun-25-2024; Generator operation in Technical Issues Jan-06-2024 A code 15 indicates an underfrequency fault. The Onan Generator Code 14 should be cleared, and power should be restored. The 1-blink and 3-blink primary codes also have secondary codes, so more blinks to display and count. Restoring Fault Code Blinking – The fault code stops blinking after five minutes (15 minutes, Series HGJAA). Most commonly this is caused by problems with the ignition system The heat causes us to run the gasoline Onan 5500 generator to power the A/C. In our case it was a code '36' and the outside temp was in the mid 90s. HTML code is Off. When I try to start it, it starts up for a few seconds, then stops, and displays a code 41, which from the manual indicates: "GENERATOR ROTATOR FAULT - Controller unable to sense field or output voltage" what is the fuel level in the motor home? the onan fuel line draws from the motorhome fuel tank. The number of times it flashes determines which code it is giving you. HGJAA, HGJAB, HGJAC, HGJAD, HGJAE, HGJAF Service Manual. Additionally, inspect the fuel filter, fuel pump, governor spring position, carburetor butterfly, and spark plugs. *****The Answer*****Onan 5500 gold marquis hgjab 5. It’s been about two years ago. The purpose of fault code 36 is to inform you that the generator has stopped without a shutdown signal from the control board, but it doesn’t really tell you what it did so. Or ask a friend or mechanic that has experience in resetting the generator if these ways do not work. Onan generator model 5500 starts runs for about 15 seconds and shuts off. Need Ideas - YouTube. Onan QG 5500 for RV Buy Online (US and Canada) Request a Quote. Registry Blogs: FAQ: Members List: iRV2 Groups: Calendar: Mark Forums Read: Log in: Mission 09-07-2010 07:15 PM: Onan Fault Code: Fossilhog: MH-General Discussions & Problems: 4: 08-06-2010 11:53 AM: Onan fault code 34: gary85: MH-General Discussions & Problems: 5: Generator still starts and surges, no nasty crap spewing out of the exhaust. 5hgjab-1038d Impco propane conversion kit onan marquis gold 5500 generator 5. 15 AM Doggy Daddy. 2 Generator Voltage is Deadly • Disable the automatic genset starting feature(AGS) of an inverter-charger or other automatic starting device before servicing the genset to avoid electric shock from an unexpected start. Blogs: FAQ: Community: Calendar: Today's Posts: Search: Log in GENERATOR ROTOR FAULT—CODE NO. New Cummins Onan generator wont stay running: BlessedGirl: Jayco Owner's Forum: 14: 09-19-2014 08:15 AM: Onan 5500 Gold wont stay on: mikey1000rr: RV Systems & Appliances: 9: 04-11-2014 06:04 PM: onan generator starts but will not stay running: tyreman3726: RV Systems & Appliances: 4: 07-17-2012 04:21 PM: onan generator wont stay My Marquis 5500 gold Onan generator calls for 15-40 oil is shell rotella t an oil I can use? 8. If you are getting the Onan generator fault code 36, start by checking the fuel pump and filters. Generator Model #5. After 30 minutes or longer, It might help to post complete Model (be sure to include Spec Code!) and Serial Number. Research indicated this is usually a faulty fuel pump or filter issue. Classifieds. Ran for 90 minutes and then shut down. FIX FAULT CODE 14: Onan 4000 generator fix, runs fine then stops >> Check out the video below: Fault code 14 means that your Onan Generator is running over frequency or too fast to function correctly. 28 Each Cummins Generator has a model/spec number description, which is shown on the serial number tag attached to the generator. e. i wonder if a new board would cure that. I have changed oil, oil filter, air filter and actually pulled the fuel line off of the carb and checked to see if the fuel pump pumped fuel. However, when the carburetor gets clogged, it negatively impacts the fuel flow, causing fault code 14. me/oldmancoffeeTOUR OF MY RV - Looks like I'm getting a fault code of 36 on my Onan 5500 generator. What is Fault Code 32 on Onan Generator. Runs two air CumminsOnan RV QG 5500 Fault Code 15 USMA_Dad. (thanks again for the help) It stopped putting out power and got the code 41. L. Reading the Fault Code on Onan Generator. Senior Member . This makes troubleshooting a little bit more difficult. Generator Set models included: HGJAA, HGJAB, I have an Onan Marquis 5500 Generator on my 33R, The Fault code is 36, which means, “Engine Stopped without Command” (really, it says that!). Onan 5500 marquis gold motorhome. Answered by Hank F. in 22 hours 3 years ago. My problem I am having with the Onan 5500 Marquis Gold onboard generator is that with the cover on and the latch closed, the generator runs for 20 minutes and then shuts off. Pingbacks are Off. 130 hrs. put some fuel in the tank and see if that. Allow the generator to run for 15 minutes, to ensure that the code has cleared. Save to My Garage. Onan HGJAB (5500) won't start. Trackbacks are Off. My onan 5500 will run 15 minutes, then shut off. It did the same thing. Your generator will be blinking in a certain pattern for Won’t stop after 15 min also won’t Show a fault code. I've checked all the obvious things. I was reading it incorrectly. The fuel pump is a component that is responsible for taking fuel from the tank and delivering it to the carburetor. That would be a big mistake. Just started. Featured your CITY, STATE, COUNTRY, NO ZIP CODES! Your account is then manually checked and approved. Pretty much everything I see on the interwebs is telling me ignition. Fortunately, the #33 code seems to be the standard overheat warning for all Onan generators including this model. Proabably over primed it. Before you can deal with the issues that can cause the fault code 33, let’s first start with determining whether it actually is fault code 33. A carburetor is one of the most common reasons behind an overworking generator. Similar Threads: Thread: Thread Thor Industries Owner's Forum: 4: 01-15-2016 07:17 AM: Onan 5500 Generator Surging: bigben: Class A Motorhome Discussions: 4: 01-10-2016 08:44 PM: Onan 8. Onan is the leading generator company across the world for RVs and campers. https: All of a sudden my RV QG 5500 generator will start and run for maybe a minute and then shut down I get codes 3,15,and 36 the oil is full pump is working Onan 5500 Generator won't stay running: DLMCGOV: RV Systems & Appliances: 7: 01-31-2023 08:35 AM: Onan generator 7500 won't stay running: Icemakker: Onan Marquis 5500 generator starts and stalls immediately. Tech4you. . Join Date: Jul Onan generators have a simple, yet elegant way of displaying fault codes, the control switch is equipped with a signal light that blinks in a certain pattern depending on the code. Release the button and start the generator. About a week ago It will run if you Onan 5500 generator tries to start but backfires through the. Registered User . Check Fuel Pump and Filters. Then, the second problem is that #33 and #44 are not assigned as fault codes by Onan. The inverter in the Onan 7500 relies on DC power produced by the diesel engine plus DC generator, and inadequate power there can cause the inverter to malfunction, making power that is not the 60 Hz frequency it should be. >> How to Fix Fault Code 15 on Onan Generator? Troubleshooting Onan LP generator fault code 36. Join Date: Aug 2015. and how do I reset the codes. On my Onan 4000, which is air cooled, if the temperature of the inlet air was very hot the generator would do a high temperature shutdown after operating 15-30 minutes, Our Onan Mobile GenSet shuts down after 10-15 minutes of operation. 15 years in property management. Output Onan 4000 -Carb replaced - now idle is high (Code 14) in First time boondocking: Our Onan RV QG 5500 will run for hours, then randomly shuts off. Back in April a park we were at in Palm Springs, had an electrical issue. Aug 20, 2018. 5HGJAB-1038. Three blinks indicates a service fault. I purchased the toy hauler used in 2009 and the generator did not run at - 1598301. “I had a resolution within 15 minutes OKAY, thank you guys for your insightful replies, I think. Generator Fault Code 32. The other day it was working fine and I shut it down as usual. Look at your amp meter ( if you have one ). it will start right back up and keep shutting Code 15 is under frequency which means the governor can't make the engine run fast enough for the load. We have already replaced the brush motor assembly and the problem is persisting. Refbacks are Off. See an authorized Onan dealer. Blogs If you google "onan code 41" you will find to service trouble shooting but without a tester it will be hard to diagnose. 5HGJAE-2135A. len k. 15 years of About Press Copyright Contact us Creators Advertise Developers Terms Privacy Press Copyright Contact us Creators Advertise Developers Terms Privacy The Onan generator fault code 41 falls among problems that don’t crop up all that often but unfortunately can mean some serious issues with a >> Code 14: Over Frequency >> Code 15: Under Frequency >> Code 19: Governor Actuator Overload >> Code 23: Low Oil ‎Feb-15-2018 01:30 PM. If you do the research on the trouble shooting Codes, a code 03 with a sub code 12 says that the inverter in the Cummins/ Onan Generator is over producing electricity for the system. Having a reliable source of electricity when you are dry camping is a necessity, but when the generator is refusing to start it is important to get to the bottom of the problem and solve it. guhzw khjwz caawl abyijo oelv tiqz gnhg cbm xazaoier whrl